[-] D100: General

Sec.7
D 100   General

Sec.7 D
101
   Except for small spaces such as air-locks, paint stores, battery rooms, etc. the lighting installation in hazardous enclosed spaces is to be divided between at least two independent circuits. One of the circuits may be emergency lights.

Sec.7 D
102
   Electrical equipment in cofferdams, ballast tanks and other spaces adjacent to crude oil tanks and pipe ducts for crude oil is to be limited to that necessary for operational reasons only.