A 400   Secondary sources of release

App.A A
401
   Typical secondary sources of release:
standard flanges, connections and valves
pumps and compressors (depending on design)
areas outside of Zone 0 or 1 if release point has varying rates and frequency of release
ventilation openings from a Zone 2 area
bell nipple (drilling nipple)
wireline stuffing box
set-back drill pipe if coated with drilling mud
gas vents from kill and choke manifold
diverter vents from drilling BOP.