The electronic pdf versions of the documents found through http://www.dnv.com/ are the officially binding versions. Copyright Det Norske Veritas.

[Book] [Expand] [Collapse] [Search Forms] [Previous Section with Hits] [Next Section with Hits] [Clear Search] [Help]

Expand Search


M500: Dropped objects [Table of Contents] M700: Abnormal wave events

DNV-OS-C201 Structural Design of Offshore Units (WSD method)

[-] Sec.14: Special Considerations for Deep Draught Floaters (DDF)
[-] M: Accidental Condition
[-] M600: Unintended flooding

Sec.14
M 600   Unintended flooding

Sec.14 M
601
   A procedure describing actions to be taken after relevant unintended flooding shall be prepared. Unintended filling of hard tanks, collision ring and bracings for a DDF will be the most relevant scenarios for the operation phase.

Sec.14 M
602
   It must be ensured that counter-filling of tanks and unit uprighting can be performed safely and without delays.

Sec.14 M
603
   Structural aspects related to the tilted condition and counter-flooding (if relevant) shall be investigated. This applies to the complete unit including risers and mooring system.

Sec.14 M
604
   If the unit can not be brought back to the design draught and verticality by counter-ballasting and redistribution of ballast water, this must be taken into account in design of the unit.
M500: Dropped objects [Table of Contents] M700: Abnormal wave events