B. Temperatures for Selection of Material

Sec.4
B 100   General

Sec.4 B
101
   The design temperature for a unit is the reference temperature for assessing areas where the unit can be transported, installed and operated.

The design temperature shall be lower or equal to the lowest mean daily temperature in air for the relevant areas. For seasonal restricted operations the lowest mean daily temperature in air for the season may be applied.

Sec.4 B
102
   The service temperatures for different parts of a unit apply for selection of structural steel.

Sec.4 B
103
   The service temperature for various structural parts is given in B200 and B300. In case different service temperatures are defined in B200 and B300 for a structural part the lower specified value shall be applied. Further details regarding service temperature for different structural elements are given in the sections for different types of units.

Sec.4 B
104
   In all cases where the temperature is reduced by localised cryogenic storage or other cooling conditions, such factors shall be taken into account in establishing the service temperatures for considered structural parts.

Sec.4
B 200   Floating units

Sec.4 B
201
   External structures above the lowest waterline shall be designed with service temperature not higher than the design temperature for the area(s) where the unit is to operate.

Sec.4 B
202
   External structures below the lowest waterline need not be designed for service temperatures lower than 0°C. A higher service temperature may be accepted if adequate supporting data can be presented relative to the lowest mean daily temperature applicable to the relevant actual water depths.

Sec.4 B
203
   Internal structures in way of permanently heated rooms need not be designed for service temperatures lower than 0°C.

Sec.4
B 300   Bottom fixed units

Sec.4 B
301
   External structures above the lowest astronomical tide (LAT) shall be designed with service temperature not higher than the design temperature.

Sec.4 B
302
   Materials in structures below the lowest astronomical tide (LAT) need not be designed for service temperatures lower than of 0°C. A higher service temperature may be accepted if adequate supporting data can be presented relative to the lowest mean daily temperature applicable for the relevant water depths.