E 500   Quality control

Ch.2 Sec.6 E
501
   The quality control shall be based on the implementation of:
bonding procedure qualification records
inspection of adhesive-bonded joints
inspection register for piping joints
inspection of finished fabricated pipework for compliance with design drawings.


Ch.2 Sec.6 E
502
   Each adhesive-bonded connection shall be permanently marked for identification purposes. A log book containing the following key values relevant for the bonding process shall be maintained:
date
temperature and relative humidity
identification number
curing temperature and time
signature of the quality inspector.