The electronic pdf versions of the documents found through http://www.dnv.com/ are the officially binding versions. Copyright Det Norske Veritas.

[Book] [Expand] [Collapse] [Search Forms] [Previous Section with Hits] [Next Section with Hits] [Clear Search] [Help]

Expand Search


A: Conditions for Retention of
Class [Table of Contents] C: Endorsement and Renewal of
the Class Certificate

DNV-OSS-102 Rules for Classification of Floating Production, Storage and Loading Units

[-] Ch.1: Generalles and Procedures for Classification
[-] Sec.5: Retention of Class
[-] B: Classification Society Involvement

Ch.1 Sec.5
B. Classification Society Involvement

Ch.1 Sec.5
B 100   Applicable rules

Ch.1 Sec.5 B
101
   Units built under the supervision of the Society shall in general be maintained and repaired in compliance with the rules to which it was constructed, except in cases mentioned in B602.

Ch.1 Sec.5 B
102
   For units built under the supervision of another IACS member society, the Society's rules in force at the same date as those enforced by the other society will be applied. If such date is not known the Society's rules in force at the "date of build" will be applied.

Ch.1 Sec.5 B
103
   For units other than those covered by 101 and 102, the Society's rules for new units in force at the time of entry into class will be applied

Ch.1 Sec.5 B
104
   Amendments to the rules may be made retroactive.

Ch.1 Sec.5 B
105
   In cases where rule amendments are made applicable to existing units at the first annual, intermediate or renewal survey after a specified date, or after the unit reaches a specified age, the expiry date of the related survey time window shall determine when the rule amendments become effective.

Ch.1 Sec.5
B 200   Surveys

Ch.1 Sec.5 B
201
   The objective of a survey shall be to ascertain that the unit, its hull structure, machinery, systems and equipment are in compliance with the rules and suitable for continued safe and reliable operation.

Ch.1 Sec.5 B
202
   A survey may consist of a combination of visual inspections, audits, measurements, functional testing, non-destructive testing and review of maintenance and other relevant records.

Ch.1 Sec.5 B
203
   The minimum extent of prescribed periodical surveys are given in Ch.3. The Society may increase the extent of a survey when deemed necessary in order to ascertain the condition of the unit.

Ch.1 Sec.5
B 300   Conditions and Memoranda

Ch.1 Sec.5 B
301
   A Conditions of Class (CC) will be imposed for the following:
repairs and/or renewals related to damage, defect or breakdown that are sufficiently serious to affect Classification (e.g. grounding, structural damages, machinery damages, wastage over the allowable limits etc.)
supplementary survey requirements
temporary repairs.


Ch.1 Sec.5 B
302
   The Society will issue a Conditions of Class (CC) when deemed necessary to carry out examinations in order to ascertain whether damage, a defect or a deficiency has been sustained or is imminent.

Ch.1 Sec.5 B
303
   A Condition of Class (CC) may contain the following:
a description of the deficiency, defect, damage or the examination required
required action
due date for the required action to be completed
possible temporary requirements imposed until the required action has been completed.

Alternatively the CC may refer to a survey report for above details. An approved repair method may be recommended as part of the required action.

Ch.1 Sec.5 B
304
   If a Condition of Class (CC) seriously affects the unit's safety and reliability, immediate action will be required. Otherwise a time limit will be given for the action to be completed.

Ch.1 Sec.5 B
305
   A Condition of Class (CC) will be deleted when the Society, through a survey or received information, has been satisfied that requested action has been satisfactory completed.

Ch.1 Sec.5 B
306
   For information related to the unit, its machinery and equipment or to rule requirements, the Society may issue an Memorandum to Owner (MO). A MO may supplement information given otherwise, e.g. in the Appendix to the class certificate or the Society's "Register of Vessels".

Ch.1 Sec.5 B
307
   An MO may be used in the following cases:
exemptions from rule requirements
accepted deviations from rule requirements
limitations on the use of the unit or its equipment
defects or deficiencies of no concern to class
deleted class notations
equipment in excess of class requirements disused
information related to agreed survey arrangements.


Ch.1 Sec.5 B
308
   Outstanding findings may be recorded as Conditions of Class or Memorandum to Owner. They will be given in writing at completion of surveys. Findings may also be communicated verbally during the course of surveys. Findings that have been corrected before the survey has been completed will not be recorded as CC.

Ch.1 Sec.5 B
309
   The Society may at any time modify a Condition of Class or Memorandum to Owner if considered appropriate. The owner will be notified accordingly.

Ch.1 Sec.5 B
310
   Conditions of Class or Memorandum to Owner are recorded in the unit's class status from where they will be deleted when no longer valid. The owner will be notified accordingly.

Ch.1 Sec.5 B
311
   The owner will be informed of Retroactive Requirements.

Ch.1 Sec.5
B 400   Survey reports and survey status

Ch.1 Sec.5 B
401
   The surveyor will prepare to the customer reports on surveys carried out.

Ch.1 Sec.5 B
402
   Survey reports may contain the following information, to the extent applicable in each case:
types of surveys carried out
certificates issued, endorsed or extended
damage, defects and/or deficiencies observed
confirmation that repairs have been completed and accepted by the surveyor
Conditions of Class (CC) issued or deleted
Memorandum to Owner (MO) issued or deleted
Retroactive Requirements (RR) issued or deleted.


Ch.1 Sec.5 B
403
   The Society will make class status reports available to customers on the Society's Internet website.

It is the customer's responsibility to obtain this information from the Society's Internet website. Survey and certificate status reports, on paper, may be distributed upon request.

Ch.1 Sec.5 B
404
   Any document issued by the Society in relation to surveys performed reflects the condition of the unit at the time of the survey only.

Ch.1 Sec.5
B 500   Damage and repairs

Ch.1 Sec.5 B
501
   Repairs shall in general be carried out in such a way that the original design and scantlings are restored. Possible design modifications or reduced scantlings based on current rules which are less stringent than those originally enforced, shall be approved by the Society before the repairs are carried out.

Ch.1 Sec.5 B
502
   Repairs to the hull structure, machinery, systems or equipment covered by the rules shall be carried out by qualified personnel and in compliance with applicable rules, with good engineering practice and under the supervision of a surveyor.

Ch.1 Sec.5 B
503
   Repairs as stipulated in 502 may be carried out without the attendance of a surveyor provided a repair plan is accepted by the Society in advance. A surveyor shall be called for acceptance of such repairs when completed.

Ch.1 Sec.5
B 600   Conversions and alterations

Ch.1 Sec.5 B
601
   Conversions or alterations of units shall in general comply with the rules applicable at the time of class assignment. If current rules are less stringent than those originally in force, then the current rules may be applied.

Ch.1 Sec.5 B
602
   When conversion or alteration involves modification which:
substantially alters the dimensions or carrying capacity of the unit (e.g. ³ 5% change in the unit's displacement), or
changes the type of unit, or
changes the main class of the unit,

the Society will decide on the rules to be applied.

Ch.1 Sec.5 B
603
   If the hull structure, machinery, systems or equipment shall be converted or altered, the changes shall be documented and be approved in the same manner as for new unit.



Ch.1 Sec.5 B
604
   Conversion or alterations shall take place under the supervision of a surveyor.
A: Conditions for Retention of
Class [Table of Contents] C: Endorsement and Renewal of
the Class Certificate