The electronic pdf versions of the documents found through http://www.dnv.com/ are the officially binding versions. Copyright Det Norske Veritas.
|
DNV-OSS-102 Rules for Classification of Floating Production, Storage and Loading Units
|
Ch.3 Sec.1
A 100 Introduction
Ch.3 Sec.1 A
101 This section states the periodical survey principles and requirements
for retention of class to objects covered by the provisions of DNV-OSS-102.
Requirements are applicable for main class, service notations and additional
class notations unless otherwise stated.
Ch.3 Sec.1 A
102 The extent of periodical surveying is presented in Sec.4 for main class, Sec.5 for additional service notations
and Sec.6 for additional
system and facility notations.
Ch.3 Sec.1 A
103 Ship-shaped offshore structures are generally treated as ships
with respect to survey of hull and equipment. Exceptions are noted
in respective survey requirements.
Ch.3 Sec.1 A
104 A Memo to Owner (MO) shall be issued stating approved changes
to survey procedures and acceptance criteria, if any. Technical
basis for approved changes shall be stated.
Ch.3 Sec.1 A
105 For column-stabilised and self-elevating
units, DNV will develop and maintain an in-service inspection program
(IIP) which will contain the structural items to be surveyed to
satisfy the requirements of main class, excluding any additional
class notations. The IIP constitutes the formal basis for surveying
structural items under main class and shall be completed to the
satisfaction of attending surveyor before renewal survey can be credited.
Ch.3 Sec.1 A
106 It is provided that every unit have implemented a maintenance
system including machinery system and equipment subject to class
(see Sec.7 Table A1). The
maintenance system shall ensure that:| — | inspections and maintenance are carried out at
defined intervals |
| — | records of these activities are maintained. |
Guidance note:
The maintenance system may be manual or computerised.---e-n-d---o-f---G-u-i-d-a-n-c-e---n-o-t-e---